NEW Product: Common Wire Adapter Kit

thermostats, Productszoning supplyComment

Sometimes, when upgrading to SmartZone or even when upgrading to a new modern thermostat without zoning, the existing wires running to the old thermostat do not have enough conductors to make it operate properly. It can sometimes be an impossible task to run a new wire to the location where the thermostat or SmartZone panel is located. For some time, we have been recommending the use of an “Add-A-Wire” kit from LUX to solve this problem but we are now offering a solution from Vine called a COMMON WIRE ADAPTER. This new solution is available at ZoningSupply.com and can be added to any thermostat that needs an additional wire.

Existing: Three (3) wires, Needed for upgrade: Four (4) wires

Existing: Four (4) wires, Needed for upgrade: Five (5) wires

Existing: Five (5) wires, Needed for upgrade: Six (6) wires


Works with any thermostat that needs a common wire. Nest, Honeywell, LUX, Vine, Braeburn, Trane, Johnson, Carrier, Bosch, and MANY MORE.

WiFi Thermosat -ST300
Sale Price:$89.99 Original Price:$99.99

ADD-A-WIRE with Zone Control

HVAC Contractors, homeowners, Other HVACzoning supplyComment

An ADD-A-WIRE device can be used when upgrading to thermostats that need a "COMMON" wire from one that didn't have one... and there is no way to run the additional wire needed.  This device, ranging from $15 to $40 can come in very handy especially in the case of zone control where one or more thermostat does not have enough wires to accomodate a modern thermostat such as a WiFi thermostat.

Be sure to follow the wiring diagram for the specific model of "ADD-A-WIRE" as well as the system type.  Show here is the LUX Products LPB-WH Power Bridge wired to a GAS/ELECTRIC thermostat and SmartZone-4X controller, however, the basic principal is the same for any application.

lux addawire instructions.jpg

All of the different ADD-A-WIRE models come with instructions, read them carefully and follow exactly and you won't have any problems.

For more information about the method of ADD-A-WIRE when there is no way to run an extra wire from your zone panel to your equipment, check out this post:
https://zoningsupply.com/blog/upgrading-thermostats-solving-a-common-problem

From an engineering perspective this is an elegant and simple solution.  Without giving away trade secrets, the ones i have tested use the a half wave bridge using diodes at the thermostat and some simple relay logic plus the another half wave at the equipment (no micro necessary) to use only 1 wire for both Y and G signals.... brilliant.

For more information, or with any questions, please contact us.

Upgrading thermostats; solving a "common" problem

HVAC Contractors, Support, homeownerszoning supply1 Comment

So, maybe you have decided to upgrade to a Wifi thermostat, or even just a standard "programmable" thermostat... only, you come to discover that your old thermostat has one less wire connected to it than the new thermostat needs.   This is usually the "24VAC Common" wire sometimes just called "C" or "24C".   This means that your old thermostat was either mechanical, power stealing, or battery operated... which isn't a problem if you don't want a modern thermostat.  MOST modern thermostats (especially WiFi) need a "C" wire from the 24V transformer to power the thermostat... this means getting a "C" wire to the thermostat.

This isn't a new problem, it started showing up in the 1980s with the first programmable thermostats... over the years, I have suggested and used several different methods to overcome this issue both with zoning and with typical single thermostat applications.  Until recently, I couldn't really recommend anything other than running a new wire... and running a new wire isn't always possible.

METHODS to add "C" Wire

  1. Run another wire to the thermostat
    The most straightforward and full-proof method is obvious: run another wire.  If possible, this is ALWAYS your best solution.
  2. Power thermostat from separate transformer
    Don't use this method... it is risky and not all thermostats support the ability to separate the "R" from the equipment transformer.
  3. Use the "G" wire for "C"
    This method DOES work but it limits the functionality of your thermostat control.  (ie. you will not be able to independently control fan from the thermostat)  The reason this works, is that the equipment automatically turns the fan on during a heating or cooling call, so the "G" wire controlling the fan from the thermostat is only necessary to turn the fan on by itself.  You will NOT be able to turn fan on from the thermostat by itself with this method.
    NOTE: This works with MOST equipment, but you should check or test before employing this method. (#3)
  4. ADD-A-WIRE Device
    It is the BEST method and really the only method I would use if a wire cannot be run.  This is a relatively new concept to me... it has been around for a few years at least but we just started recommending it within the last 2 years.    Several companies have started offering an "ADD-A-WIRE" device that allows the addition of a "COMMON" wire.  These devices range from $15 - $40 and are very simple to wire (you have to be able to get to your equipment furnace/blower). 
lux addawire.JPG

How an ADD-A-WIRE Device works:

venstar addawire.JPG

It will come in 2 pieces, one is a small box with several connections labled "R", "C", "Y", "G", "W".  You will follow the included wiring instructions to connect this box at your indoor HVAC equipment.  The other piece that comes with the ADD-A-WIRE is a wiring connector with 3 leads, this connects at the back of your thermostat as shown in the wiring instructions.
Once these two pieces are wired properly you will have the "C" you need for any thermostat... it's almost like magic (electrical engineering magic).

NOTE: Make sure all wiring is done with the power to the HVAC equipment OFF at the breaker.

A few different models to choose from (prices on amazon at time of writing)  There are many others available but they all do the same thing (NOTE: we are not compensated by any of these companies or any others for our opinions):

For more information about specific use with zoning and zone control systems such as SmartZone... contact us

Another thing to consider:  The ecobee3 and ecobee3 LITE both come with an "ADD-A-WIRE" type device.  So, if you are thinking about a WiFi thermostat and are afraid you will need to add a wire... keep the ecobee in mind.  See our WiFi stat roundup for more info